What your engineer reviews.

These are representative examples of the systems, conditions and tests documented during an inspection—not a complete list. Every photograph is paired with written context in the report, and the scope covers these items and more where visible, accessible and safe.

Electric range operating during a home inspection
Installed appliance operationAccessible installed kitchen and laundry appliances are operated under normal conditions when safe and available.
Electrical receptacle checked with a voltage tester
Receptacles and switchesRepresentative accessible devices are checked for basic operation and visible safety concerns.
Electrical service equipment documented during inspection
Electrical service and panelsService equipment, panel condition, visible wiring and accessible overcurrent protection are documented.
Sink supply and drainage components reviewed during inspection
Visible plumbingAccessible supply, drainage, fixtures, shutoffs and leakage indicators are reviewed in context.
Heating equipment controls documented during inspection
Heating and cooling equipmentInstalled equipment, distribution, thermostats and accessible ventilation components are reviewed and operated where conditions allow.
Wall thermostat operating during a home inspection
Controls and thermostatsAccessible controls are used to confirm a response from the connected equipment under normal settings.
Accessible roof framing and insulation visible inside an attic
Attic, insulation and ventilationVisible framing, sheathing, insulation, ventilation and moisture indicators are reviewed where access is safe.
Roof flashing and penetration photographed by drone
Roof detailsAerial imagery documents roof planes, flashings, penetrations and areas that cannot be safely reached on foot.
Foundation wall with visible moisture-related deterioration
Foundation and moisture patternsVisible conditions are considered alongside grading, drainage, structure and signs of ongoing water movement.
Concealed moisture damage exposed behind an interior wall finish
Moisture investigationStaining, material deterioration and thermal or moisture patterns are documented with practical next-step recommendations.

A home is more than the finishes you can see.

Structure, moisture, drainage, mechanical equipment, electrical service and the roof all affect one another. An experienced structural engineer knows how to connect those observations instead of treating each room as a checklist.

The result is a clearer understanding of what matters now, what can be maintained and what deserves specialist attention.

From the site to the service panel.

One thorough inspection standard for purchases, pre-listing, maintenance, new construction, PDI and warranty reviews.

01

Structure and foundation

Visible foundations, framing, load paths, movement, cracking and signs that warrant deeper engineering review.

02

Exterior and site

Cladding, grading, drainage, walks, decks, porches, retaining conditions and how water moves around the home.

03

Roof and drainage

Roof coverings, flashings, penetrations, chimneys, gutters and inaccessible areas reviewed with aerial drone imagery where conditions allow.

04

Attic and insulation

Roof framing, sheathing, ventilation, visible insulation, moisture indicators and accessible air-leakage conditions.

05

Electrical

Service equipment, panels, visible wiring, receptacles, switches, fixtures and accessible safety devices.

06

Plumbing

Visible supply, drainage and venting, fixtures, shutoffs, water-heating equipment, leakage indicators and water pressure.

07

Heating and cooling

Furnaces, boilers, air conditioning, heat pumps, distribution, thermostats and visible ventilation components.

08

Interior and life safety

Walls, ceilings, floors, windows, doors, stairs, guards, smoke alarms and accessible carbon-monoxide alarms.

09

Kitchen and laundry

Visible connections and basic operation of accessible installed appliances under normal operating conditions.

10

Moisture and thermal review

Thermal imaging and targeted moisture investigation used to identify patterns that may not be visible at the surface.

Testing is limited to components that are visible, accessible, safe to operate and available under the conditions present at the inspection. Destructive testing is not performed unless separately agreed in writing.

Tools used to answer specific questions.

Aerial roof review

Drone imagery helps document roof planes, penetrations, flashings and areas that cannot be safely walked.

Thermal imaging

Temperature patterns can support the investigation of insulation gaps, air leakage and possible moisture conditions.

Targeted testing

Water pressure, accessible receptacles, equipment controls and installed appliances are checked under normal conditions.

Electrical service equipment documented during inspectionAccessible sink plumbing reviewed during inspection

A useful record of what was found.

Your report is organized to support decisions, not overwhelm them.

Photo-documented observationsImmediate safety concernsMajor repairs and further reviewMaintenance and planning itemsPractical next steps

When an issue needs design, repair or specialist investigation, Kernel can help define the next scope and coordinate qualified engineering or trade support.

Concealed moisture damage exposed behind an interior wall finish

Connect visible conditions to likely causes.

A stain, a crack or an uneven floor is an observation. Engineering experience helps determine what it may be connected to and what should happen next.

BuyingUnderstand the building before closing.
SellingIdentify concerns before they become surprises.
MaintainingPlan repairs and upgrades with context.
New constructionDocument deficiencies at key handover stages.

Make the next decision with a clearer picture.

Send the property address, timing and any concerns you already have. An engineer will confirm availability and the inspection scope.